EasyManuals Logo
Home>Tektronix>Power Supply>PS280

Tektronix PS280 User Manual

Tektronix PS280
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
Reference
14
PS280 & PS283 User Manual
5V FIXED 3A
GND
GND
SLAVE MASTER
Load 2 Load 1
0 to 2 A (PS280)
0 to 1 A (PS283)
–5 V
3A
–5 TO +25 V
Load 3
0 to 2 A (PS280)
0 to 1 A (PS283)
–5 TO +25 V
Figure 5: Independent Common Ground-Referenced Application
In this configuration, each of the variable power supplies can be
varied from –5 V to +25 V (+30 V overall). The GND post becomes
the relative negative terminal for both variable outputs. Because the
variable power supplies are referenced to –5 V, the LED display,
when set to display volts, shows a value that is five volts lower than
the actual output.
For example, the LED display indicates:
H 0 V when the output is –5 V
H 5 V when the output is 0 V
H 30 V when the output is 25 V
Negative 5 V is available between GND and the negative terminal of
the FIXED 5 V power supply.
To test a circuit in the independently ground-referenced mode,
follow these steps:
1. Turn the POWER off to the PS280 or PS283.
2. Connect the outputs as shown in Figure 5.
3. Set both variable supply VOLTAGE controls to the minimum
setting.

Other manuals for Tektronix PS280

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix PS280 and is the answer not in the manual?

Tektronix PS280 Specifications

General IconGeneral
BrandTektronix
ModelPS280
CategoryPower Supply
LanguageEnglish

Related product manuals