DMM91X Series Specifications
Handheld and Benchtop Instruments Basic Service
5
Table 3: Measurement Characteristics (Cont.)
Characteristic Description
C
o
m
pliance voltages (t
y
pical) 1 V (W setting)
0.4 V (LV setting)
Continuity threshold
3
Beeper sounds when resistance is approximately 75 W or less
Diode test
3
Test current (typical) 0.6 mA
Test voltage (typical) 3 V
Capacitance
Ranges 4 nF, 40 nF, 400 nF, 4 mF, 40 mF, 400 mF, 4 mF, 40 mF
Accuracy
3
(% + 10 count)
4 nF to 4 mF ±1% (delta mode)
40 mF to 40 mF ±3%
Frequency
4
Ranges 400 Hz, 4 kHz, 40 kHz, 400 kHz, 2 MHz
Accuracy
6
(% + 10 count)
400 Hz to 400 kHz ±0.01%
2 MHz ±0.15%
Sensitivity 0.5 V
p-p
Duty factor
Accuracy ±(0.1% + 0.05% per kHz) for 5 V input
Range 15 Hz to 10 kHz (10% to 90% duty factor)
Temperature
Range –50_ to +980_ C
Accuracy 2_ C
Thermocouple type K
Peak measurements
3
Accuracy DC volts: ±5% + 40 counts of the peak value of a single 1 ms pulse
1
Divide counts by 10 in 4000 count mode.
2
750 V, 40 M–LV range unspecified.
3
4000 count mode only.
4
Upper display readout is limited to 10 kHz with reduced accuracy.
5
>10% range, 4 V range > 1 V.
6
>5% range.

Table of Contents

Other manuals for Tektronix TAS 200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TAS 200 Series and is the answer not in the manual?

Tektronix TAS 200 Series Specifications

General IconGeneral
BrandTektronix
ModelTAS 200 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals