PS2520 Series Specifications
Handheld and Benchtop Instruments Basic Service
5
Table 1: Operational Characteristics (Cont.)
Characteristic Description
Parallel Tracking
Program Accuracy
Voltage ≤0.05% + 25 mV (50 mV if rating voltage > 36 V)
Current ≤0.2% + 20 mA
Overvoltage Protection ≤2% + 0.6 V
Load Effect
Voltage ≤3 mV rear output (≤6 mV front output)
Current ≤6 mA (≤12 mA if rating current > 3.5 A)
Source Effect
Voltage ≤3 mV
Current ≤6 mA
GPIB Capability (Optional IEEE-488.2) SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT0, C0, E1
Memory Locations (Store and Recall) 00 to 49 (50 locations)
Timer
Setting Time 1 to 65535 seconds
Resolution 1 second
Table 2: Electrical Characteristics
Characteristic Description
Power Source 100, 120, and 220 VAC ±10% at 50 to 60 Hz
240 VAC –10%, +4.2%, at 50 to 60 Hz
Safety ETL listed to UL 1244
Certified to CSA-C22.2 No 231-M89
Table 3: Environmental Characteristics
Characteristic Description
Operating Temperature 0_ to 40_ C (32_ to 104_ F)
Nonoperating Temperature –10_ to +70_ C (14_ to 158_ F)