www.ti.com
Added Features
11
SLUUBM6–March 2018
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
Overview
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Pre-Charging Current I2 0 32767 100 mA
Description: Pre-charge ChargingCurrent()
3.2.8 Maintenance Charging
Maintenance Charging → Current is added.
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
MCHG Current I2 0 32767 44 mA
Description: Maintenance ChargingCurrent()
3.2.9 Voltage Range
The following dataflash are added:
• Voltage Range → Pre-charge Start Voltage
• Voltage Range → Charging Voltage Low
• Voltage Range → Charging Voltage Med
• Voltage Range → Charging Voltage High
• Voltage Range → Charging Voltage Hysteresis
3.2.9.1 Pre-Charge Start Voltage
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Voltage Range
Pre-charge Start
Voltage
I2 0 32767 2500 mV
Description: Minimum cell voltage to enter PRECHARGE mode
3.2.9.2
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Voltage Range
Charging Voltage
Low
I2 0 32767 2900 mV
Description: Pre-charge Voltage range to Charging Voltage Low range
3.2.9.3 Charging Voltage Med
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Voltage Range
Charging Voltage
Med
I2 0 32767 3600 mV
Description: Charging Voltage Low range to Charging Voltage Med range.