www.ti.com
Added Features
7
SLUUBM6–March 2018
Submit Documentation Feedback
Copyright © 2018, Texas Instruments Incorporated
Overview
3.2.1.3 T5 Temp
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Temperature
Ranges
T5 Temp I1 –128 127 20 °C
Description: T5 recommended temperature range lower limit
3.2.1.4 T6 Temp
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Temperature
Ranges
T6 Temp I1 –128 127 25 °C
Description: T6 recommended temperature range upper limit
3.2.1.5 T3 Temp
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Temperature
Ranges
T3 Temp I1 –128 127 30 °C
Description: T3 standard temperature range to high temperature range
3.2.1.6 T4 Temp
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Temperature
Ranges
T4 Temp I1 –128 127 55 °C
Description: T4 high temperature range upper limit
3.2.1.7 Hysteresis
Class Subclass Name Type Min Max Default Unit
Advanced Charging
Algorithms
Temperature
Ranges
Hysteresis Temp I1 –128 127 1 °C
Description: Temperature Hysteresis, applied when temperature is decreasing.
3.2.2 Fast Charging
Fast Charging → Voltage and Current is replaced with:
• Low Temp Charging → Voltage
• Low Temp Charging → Current Low
• Low Temp Charging → Current Med
• Low Temp Charging → Current High
• Standard Temp Charging → Voltage
• Standard Temp Charging → Current Low
• Standard Temp Charging → Current Med
• Standard Temp Charging → Current High
• High Temp Charging → Voltage