Table 3-2 describes and lists the connections and configuration for J6. Use J6 to switch between different DCL
connections to test different duty cycle limits. Pin 1 is noted by the dot next to the pin.
Table 3-2. J6 Connections and Configuration
Pin Connection Duty Cycle Limit Configuration Description
Pin 1 and Pin 2 100% DCL is connected high to VLDO
Pin 2 and Pin 3 50% DCL is connected low to AVSS
Floating 75% DCL is left floating
EVM Connectors and Test Points www.ti.com
6 TPS7H5001-SP Evaluation Module SLVUBZ8 – JULY 2021