4 INS037-5
Address DIP 1 DIP 2 DIP 3 DIP 4
1 N/A Off Off Off
2N/AOffOffOn
3N/AOffOn Off
4N/AOffOn On
5N/AOn Off Off
6N/AOn Off On
1. NEVER set two RKPs to the same address.
2. Keypads are factory set to address 1.
3. If the keypad is powered but offline (i.e. T and R not
connected) the zone LED corresponding to the
address currently selected will light.
4. If an invalid address is selected the keypad will
sound an error tone.
1.4 Programming
When the system is powered up it automatically checks
and configures all connected keypads. It is strongly
recommended that the system is completely powered
down (mains and battery) before wiring a keypad. If a
keypad is added without removing power then it must be
configured as follows: