Creation: 01.31 - 2014
1-2-3
GPU - 406
(b) Each contactor is identified by a nameplate. Each cable should be identified by a band-type
marker. Connect cable "A" to terminal "A", "B” to "B", etc. Tighten the terminal nuts
securely. Connect the "E" lead to the "E" terminal and the "F" lead to the "F" terminal on the
distribution block below the contactor.
(c) Tighten the cable clamps securely, but avoid damage to the cable insulation.
NOTE:
The AC aircraft cable assembly recommended shall consist of
four single conductor #2/0 cables with two #12 control leads
connected to an AN3430 plug.
The #2/0 cables must be equipped with terminals having a 3/8
Inch diameter mounting hole. The mounting hole in the #12
leads must be 1/4 Inch.