Care and service
DE EN
page 45 / 117
8.3 Maintenance intervals
If the prescribed maintenance intervals are not complied with or documented, the guarantee and warranty become void. Ensure that the services carried out are documented
in your service check folder.
Check by the customer before every use
Component Activity
Emergency Stop Switch Check functionality
Complete system Visual inspection of all components
Cooling systems Check/clean filters
Pumps Check flow
Connections/hoses Check for leaks
Check attachmentVenting of high-voltage battery (op-
tional)
Check draining openings
Check by the customer (O) or by Torqeedo technician (X)
Overall system Activity 1000 h/annually Special intervals
All system components Check attachment O
Motor and battery Check fastening and torque of screws, bolts X
Check seal of cable glands X
Confirm full insulation X
Cable connections for HV, 12 V, 24 V, data
Visual inspection of all HV connections X

Table of Contents