EasyManuals Logo
Home>Toshiba>Power Supply>TOSVERT VF-PS1

Toshiba TOSVERT VF-PS1 User Manual

Toshiba TOSVERT VF-PS1
317 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #214 background imageLoading...
Page #214 background image
E6581386
H-6
8
8.3 Changing status monitor function
Changing the display format while power is on
The item displayed in the standard monitor mode (*1 on the left side of table on page H-2), for example, operation
frequency which is displayed by default in this way: “=” when power is on or “” when power is off, can be
changed to any item shown on page H-7. This new format, however, will not display an assigned prefix such as
or .
Standard monitor mode Standard monitor display selection ()
Title Function Adjustment range Default setting

Standard monitor hold
function
:Real time
:Peak hold
:Minimum hold


Standard monitor
display selection
~
Refer to page H-7.

If  is set to , the monitored values selected with  (standard monitor display selection parameter) are
displayed one after another.
If  is set to or , the monitored values indicate the maximum or minimum values in each operation mode.
When the inverter not running, the monitored values indicate the last hold value.
The peak hold and minimum hold values are not reset by the motor is in operation or in standstill. The monitor is
displayed values after turned on the power or after the reset with the EASY key.
Changing contents of status monitor indication
Regarding contents of status monitor indications appearing in the left column of the table on page H-2, those
marked with *2 to *5 can be changed for others. Select a desirable monitor function from among optional monitor
functions appearing on page H-7.
*2 Frequency command
Changeable by status monitor 1 display selection ().
*3 Output current
Changeable by status monitor 2 display selection ().
*4 Input voltage
Changeable by status monitor 3 display selection ().
*5 Output voltage
Changeable by status monitor 4 display selection ().
Title Function Adjustment range Default setting
 Status monitor 1 display selection ~ Refer to page H-7. 
 Status monitor 2 display selection Ditto 
 Status monitor 3 display selection Ditto 
 Status monitor 4 display selection Ditto 
*If  to  are set at “” (Output frequency) the operation frequency is not held in trip status.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-PS1 and is the answer not in the manual?

Toshiba TOSVERT VF-PS1 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-PS1
CategoryPower Supply
LanguageEnglish

Related product manuals