EasyManuals Logo
Home>Toshiba>Power Supply>TOSVERT VF-PS1

Toshiba TOSVERT VF-PS1 User Manual

Toshiba TOSVERT VF-PS1
317 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
E6581386
5
I
Operations
Warning
Reference
Prohibited
Do not touch inverter terminals when electrical power is applied to the inverter even if the
motor is stopped.
Touching the inverter terminals while power is connected to it may result in electric shock.
Do not touch switches when hands are wet and do not try to clean the inverter with a damp
cloth.
Such practices may result in electric shock.
Do not go near the motor in alarm-stop status when the retry function is selected.
The motor may suddenly restart and that could result in injury.
Take measures for safety, e.g. attaching a cover to the motor, against accidents when the
motor unexpectedly restarts.
The inverter is tuned automatically (auto-tuning =, ) when the inverter is started
for the first time after setup.
During auto-tuning, which takes about 3 minutes from several seconds as each model, the
motor is energized, although it is standing still. The motor may produce noise during
auto-tuning, which, however, does not indicate that something is wrong with the inverter or
the motor.
Do not set the stall prevention level () extremely low.
If the stall prevention level parameter () is set at or below the no-load current of the
motor, the stall preventive function will always be active and increase the frequency when it
judges that regenerative braking is taking place.
Do not set the stall prevention level parameter () below 30% under normal use
conditions.
3.
3.
3.
6.19
6.26.1
Mandatory
Do not turn on the power before attaching the front cover.
When storing inside the cabinet and using with the front cover removed, always close the
cabinet doors first and then turn power on. If the power is turned on with the front cover or
the cabinet doors open, it may result in electric shock.
Make sure that operation signals are off before resetting the inverter after malfunction.
If the inverter is reset before turning off the operating signal, the motor may restart
suddenly causing injury.
Provide cranes and hoists with sufficient circuit protection such as mechanical braking.
Without sufficient circuit protection, the resulting insufficient motor torque during tuning
could create a risk of machine stalling/falling.
3.
10.
3.
6.19
Caution
Reference
Mandatory
Observe all permissible operating ranges of motors and mechanical equipment. (Refer to
the motor's instruction manual)
Not observing these ranges may result in injury.
3.
When sequence for restart after a momentary failure is selected
Caution
Reference
Mandatory
Stand clear of motors and mechanical equipment.
If the motor stops due to a momentary power failure, the equipment will start suddenly
when power is restored.
This could result in unexpected injury.
Attach cautions about sudden restart after a momentary power failure on inverters, motors
and equipment for prevention of accidents in advance.
5.18.1
When retry function is selected
Caution
Reference
Mandatory
Stand clear of motors and equipment.
If the motor and equipment stop when the alarm is given, selection of the retry function will
restart them suddenly after the specified time has elapsed and alarm condition has
disappeared. This could result in unexpected injury.
To prevent accidents, stick caution notices that the inverter has a retry function to the
inverter, the motor and the machine.
6.15.1

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba TOSVERT VF-PS1 and is the answer not in the manual?

Toshiba TOSVERT VF-PS1 Specifications

General IconGeneral
BrandToshiba
ModelTOSVERT VF-PS1
CategoryPower Supply
LanguageEnglish

Related product manuals