Page 19
Installer’s Guide
COMMON
FAN
COMPRSSOR
1ST STAGE ELECTRIC HEAT
2ND STAGE ELECTRIC HEAT
SWITCHOVER VALVE
DEFROST CONTROL 'T' SIGNAL
24 VOLTS
B
G
Y
W1
W2
O
T
R
UNIT LOW VOLTAGE AREA
TYPICAL THERMOSTAT
UNIT HEATER AREA
ELECTRIC
HEATER
CONTROL
BOX
POLARIZED
PLUG
UNIT CONTROL BOX
3 PH
POWER
UNIT
NOTE 1,8
3 PH
POWER
HEATER
1 PH
POWER
1 PH
POWER
UNIT CONTROL
BOX
UNIT HEATER AREA
FACTORY PROVIDED
FIELD CONNECTED
WIRES
(BL)
(YL)
(GR)
(PR)
(OR)
(OR)
B
G
Y
W1
W2
O
T
R
(BR)
(RD)
(GR)
(BL)
(WH)
(WH)
(YL)
(OR)
1 PH
POWER
3 PH
POWER
GROUND
WIRE
SINGLE POWR ENTRY
W1
W2
(WH)
(WH)
W1
W2
(WH)
(WH)
HEATER SECOND STAGE AMBIENT
TEMPERATURE LOCKOUT
NOTE 7,8
UNIT LOW
VOLTAGE
AREA
OUTDOOR
THERMOSTAT
ACCESSORY
BAYSTAT033A
NOTE 10
HEATER AMBIENT
TEMPERATURE LOCKOUT
NOTE 7,8
UNIT LOW
VOLTAGE
AREA
OUTDOOR
THERMOSTAT
ACCESSORY
BAYSTAT033A
NOTE 10
TYPICAL THERMOSTAT
TYPICAL THERMOSTAT
TYPICAL 2-STAGE
THERMOSTAT
UNIT LOW
VOLTAGE AREA
UNIT LOW
VOLTAGE AREA
TO COMPR.
CONTACTOR
ELECTRIC
HEATER
CONTROL
BOX
HEATER
FUSES
UNIT
FUSES
SPE
ACCESSORY
KIT
TO ECONOMIZER
FACTORY PROVIDED
FIELD INSTALLED WIRES
NOTE 9
(NOT APPLICABLE TO THE
WCM---F MODELS)
FIG. 3 OUTDOOR THERMOSTAT ACCESSORY CONNECTIONS
FIG. 1
SINGLE POWER ENTRY ACCESSORY CONNECTIONS
FIG. 2
ECONOMIZER ACCESSORY
CONNECTIONS
GROUND
WIRE
Figure 20. WC Field Wiring Diagram
NOTES:
1. FUSED DISCONNECT SIZE, POWER WIRING AND
GROUNDING OF EQUIPMENT MUST COMPLY
WITH CODES.
2. BE SURE POWER SUPPLY AGREES WITH
EQUIPMENT AND HEATER NAMEPLATE.
3. LOW VOLTAGE WIRING TO BE 18 AWG MINIMUM
CONDUCTOR.
4. SEE HEATER NAMEPLATE FOR CURRENT
RATING OF HEATER USED.
5. SEE UNIT AND HEATER DIAGRAM FOR
ELECTRICAL CONNECTION DETAILS.
6. IF ELECTRIC HEATER ACCESSORY IS NOT
INSTALLED OMIT THE ELECTRIC HEATER,
ASSOCIATED POWER WIRES AND THE ‘W’ AND
‘X2’ THERMOSTAT WIRES.
7. FIG. 3 DEMONSTRATES CONNECTION OF THE
OUTDOOR THERMOSTAT ACCESSORY ONLY.
FOR FURTHER UNIT CONNECTION DETAILS
REFER TO THE OTHER FIGURES.
8. THE 41A(BR) WIRE IS FIRST STAGE ELECTRIC
HEAT. IF THE ELECTRIC HEATER ACCESSORY
HAS TWO HEATING STAGES THE 41C(BR) WIRE
IS SECOND STAGE ELECTRIC HEAT.
9. WHEN THE BAYECON054A OR –055A
ECONOMIZER IS INSTALLED THE BAYRLAY003
RELAY ACCESSORY KIT IS REQUIRED TO
INTERFACE THE ECONOMIZER TO THE HEAT
PUMP FOR PROPER SYSTEM OPERATION.
WHEN THE BAYECON054B OR –055B OR 073A
ECONOMIZER IS INSTALLED, THE
BAYRLAY004A RELAY ACCESSORY KIT IS
REQUIRED TO INTERFACE THE ECONOMIZER TO
THE HEAT PUMP FOR PROPER SYSTEM
OPERATION.
10. THE BAYSTAT033A OUTDOOR THERMOSTAT
ACCESSORY KIT CONTAINS A THERMOSTAT
AND A RELAY. THE RELAY IS NOT REQUIRED
TO BE USED IN THIS APPLICATION.
Field Wiring Diagram

Questions and Answers: