Model Number Descriptions
DIGIT 14 - SUPPLY AIR FAN HP
1 = 3 HP 4 = 10 HP 7 = 25 HP
2 = 5 HP 5 = 15 HP 8 = 30 HP
3 = 7.5 HP 6 = 20 HP 9 = 40 HP
DIGIT 15 - SUPPLY AIR FAN
DRIVE
5 = 500 RPM B = 1100 RPM
6 = 600 RPM C = 1200 RPM
7 = 700 RPM D = 1300 RPM
8 = 800 RPM E = 1400 RPM
9 = 900 RPM F = 1500 RPM
A=1000 RPM
DIGIT 16 - FRESH AIR
A = No Fresh Air
B = 0-25% Manual
D = 0-100% Economizer
DIGIT 17 - SYSTEM CONTROL
1 = CV - Zone Temperature Control
2 = CV - Discharge Temperature Control
4 = CV - Zone Temperature Control
Space Pressure Control w/
Exhaust/Return VFD w/o Bypass
5 = CV - Zone Temperature Control
Space Pressure Control w/
Exhaust/Return VFD and Bypass
6 = VAV Discharge Temperature Control
w/ VFD w/o Bypass
7 = VAV Discharge Temperature Control
w/ VFD and Bypass
8 = VAV Discharge Temperature Control
Supply and Exhaust/Return Fan w/
VFD w/o Bypass
9 = VAV Discharge Temperature
Control Supply and Exhaust/Return
Fan with VFD and Bypass
A = VAV – Single Zone VAV – w/ VFD
w/o Bypass
B = VAV – Single Zone VAV – w/ VFD
w/ Bypass
C = VAV – Single Zone VAV – Supply and
Exhaust/Return Fan w/ VFD
w/o Bypass
D = VAV – Single Zone VAV – Supply and
Exhaust/Return Fan w/ VFD w/ Bypass
DIGIT 18 - ZONE SENSOR
0=None
A = Dual Setpoint Manual or Auto
Changeover (BAYSENS108*)
B = Dual Setpoint Manual or Auto
Changeover w/ System Function
Lights (BAYSENS110*)
C = Room Sensor w/ Override and
Cancel Buttons (BAYSENS073*)
D = Room Sensor w/ Temperature
Adjustment and Override and
Cancel Buttons (BAYSENS074*)
L = Programmable Zone Sensor w/
System Function Lights for both
CV and VAV (BAYSENS119*)
Note: *Asterisk indicates current model
number digit A, B, C, etc. These
sensors can be ordered to ship
with the unit.
DIGIT 19 - AMBIENT CONTROL
0=Standard
1 = 0° Fahrenheit
DIGIT 20 - AGENCY APPROVAL
0 = None (cULus Gas Heater, see note)
1=cULus
Note: Includes cULus classified gas
heating section only when second
digit of Model No. is a "F."
DIGITS 21 - 38 -
MISCELLANEOUS
21 A = Unit Disconnect Switch
22 B = Hot Gas Bypass
C = Hot Gas Reheat w/out Hot Gas
Bypass
D = Hot Gas Reheat and Hot Gas
Bypass
23 0 = Without Economizer
C = Economizer Control w/
Comparative Enthalpy
Z = Economizer Control w/
Reference Enthalpy
W = Economizer Control w/Dry Bulb
24 E = Low Leak Fresh Air Dampers
25 F = High Duct Temperature
Thermostat
26 G = High Capacity
27 * = Air-Cooled Aluminum
Condenser Coil
J = Corrosion Protected Condenser
Coil
A = Evap Condenser
B = Evap Condenser w/ Sump
Heater
C = Evap Condenser w/ Dolphin
WaterCare System
D = Evap Condenser w/ Sump
Heater and Dolphin WaterCare
System
E = Evap Condenser w/
Conductivity Controller
F = Evap Condenser w/
Conductivity Controller and
Sump Heater
Tip: EXAMPLE
Model numbers:
SAHL*5040A68A6BD800100W00
G0B000R000800 describes a unit
with the following characteristics:
DX Cooling Only unit w/ no
extended casing, 50 ton nominal
cooling capacity, 460/60/3 power
supply,100 percent exhaust with
Statitrac, 10 HP exhaust fan motor
with drive selection No. 8 (800
RPM), throwaway filters, 20 HP
supply fan motor with drive
selection No. B (1100 RPM), 0-
100% economizer w/ dry bulb
control, supply and exhaust VFD
w/o bypass, no remote panel,
standard ambient control, cULus
agency approval. High capacity
unit, extended grease lines and
spring isolators.
The service digit for each model
number contains 38 digits; all 38
digits must be referenced.
28 B = GBAS 0-10V
K=GBAS 0-5V
R=Rapid Restart
30 M = Remote Human Interface
31 N = Ventilation Override Module
32 R = Extended Grease Lines
33 T = Access Doors
34 V = Inter-Processor
Communication Bridge
35 M = BACnet Communication
Interface (BCI) Module
Y = Trane Communication Interface
(TCI) Module
7 = Trane LonTalk Communication
Interface (LCI) Module
36 8 = Spring Isolators
37 6 = Factory-Powered 15A GFI
Convenience Outlet/Disconnect
Switch
38 J = Temperature Sensor

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane IntelliPak SAHL Series and is the answer not in the manual?

Trane IntelliPak SAHL Series Specifications

General IconGeneral
BrandTrane
ModelIntelliPak SAHL Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals