RT-SVX36G-EN 13
General Information
Commonly Used Acronyms
For convenience, a number of acronyms and abbreviations are used throughout this manual. These
acronyms are alphabetically listed and defined below.
Unit Description
Each Trane commercial, single-zone rooftop air conditioner ships fully assembled and charged with
the proper refrigerant quantity from the factory.
An optional roof curb, specifically designed for the S_HL units is available from Trane. The roof curb
kit must be field assembled and installed according to the latest edition of the curb installation
guide.
Trane Commercial Rooftop Units are controlled by a microelectronic control system that consists
of a network of modules and are referred to as Unit Control Modules (UCM). The acronym UCM
is used extensively throughout this document when referring to the control system network.
These modules through Proportional/Integral control algorithms perform specific unit functions
which provide the best possible comfort level for the customer.
They are mounted in the control panel and are factory wired to their respective internal
components. They receive and interpret information from other unit modules, sensors, remote
panels, and customer binary contacts to satisfy the applicable request for economizing, mechanical
cooling, heating, and ventilation. Refer to the following discussion for an explanation of each
module function.
Rooftop Module (RTM - 1U48 Standard on all units)
The Rooftop Module (RTM) responds to cooling, heating, and ventilation requests by energizing
the proper unit components based on information received from other unit modules, sensors,
remote panels, and customer supplied binary inputs. It initiates supply fan, exhaust fan, exhaust
damper, return fan, return damper, variable frequency drive output, and economizer operation
based on that information.
AC = Air Cooled Condenser MDM = Modulating Dehumidification Module
BAS = Building automation systems MPM = Multipurpose module
BCI = BACnet Communication Interface module MWU = Morning warm-up
CFM = Cubic-feet-per-minute NSB = Night setback
CKT. = Circuit O/A = Outside air
CLV = Cooling valve (reheat only) psig = Pounds-per-square-inch, gauge pressure
CV = Constant volume PTFE = Polytetrafluoroethylene (Teflon®)
CW = Clockwise R/A = Return air
CCW = Counterclockwise RAH = Return air humidity
E/A = Exhaust air RH = Right-hand
EC = Evaporative Condenser RHP = Reheat pumpout solenoid valve
ECEM = Exhaust/comparative enthalpy module RHV = Reheat valve
F/A = Fresh air RPM = Revolutions-per-minute
GBAS = Generic building automation system RT = Rooftop unit
HGBP = Hot gas bypass RTM = Rooftop module
HGRH = Hot gas reheat S/A = Supply air
HI = Human Interface SCM = Single circuit module
HVAC = Heating, ventilation and air conditioning SZ = Single-zone (unit airflow)
I/O = Inputs/outputs SZVAV = Single zone variable air volume
IOM = Installation/operation/ maintenance manual TCI = Tracer communications module
IPC = Interprocessor communications UCM = Unit control modules
IPCB = Interprocessor communications bridge VAV = Variable air volume
LCI-I = LonTalk Communication Interface for IntelliPak VCM = Ventilation control module
LH = Left-hand VOM = Ventilation override module
MCHE = Microchannel Coil w.c. = Water column
MCM = Multiple compressor module WCI = Wireless Communication Interface

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane IntelliPak SAHL Series and is the answer not in the manual?

Trane IntelliPak SAHL Series Specifications

General IconGeneral
BrandTrane
ModelIntelliPak SAHL Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals