Cleaning Coil Fin
WWAARRNNIINNGG
HHaazzaarrddoouuss CChheemmiiccaallss!!
CCooiill cclleeaanniinngg aaggeennttss ccaann bbee eeiitthheerr aacciiddiicc oorr hhiigghhllyy
aallkkaalliinnee aanndd ccaann bbuurrnn sseevveerreellyy iiff ccoonnttaacctt wwiitthh sskkiinn
oorr eeyyeess ooccccuurrss..
HHaannddllee cchheemmiiccaall ccaarreeffuullllyy aanndd aavvooiidd ccoonnttaacctt wwiitthh
sskkiinn.. AALLWWAAYYSS wweeaarr PPeerrssoonnaall PPrrootteeccttiivvee
EEqquuiippmmeenntt ((PPPPEE)) iinncclluuddiinngg ggoogggglleess oorr ffaaccee sshhiieelldd,,
cchheemmiiccaall rreessiissttaanntt gglloovveess,, bboooottss,, aapprroonn oorr ssuuiitt aass
rreeqquuiirreedd.. FFoorr ppeerrssoonnaall ssaaffeettyy rreeffeerr ttoo tthhee cclleeaanniinngg
aaggeenntt mmaannuuffaaccttuurreerr’’ss MMaatteerriiaallss SSaaffeettyy DDaattaa SShheeeett
aanndd ffoollllooww aallll rreeccoommmmeennddeedd ssaaffee hhaannddlliinngg
pprraaccttiicceess..
WWAARRNNIINNGG
HHaazzaarrddoouuss VVoollttaaggee ww//CCaappaacciittoorrss!!
FFaaiilluurree ttoo ddiissccoonnnneecctt ppoowweerr aanndd ddiisscchhaarrggee
ccaappaacciittoorrss bbeeffoorree sseerrvviicciinngg ccoouulldd rreessuulltt iinn ddeeaatthh oorr
sseerriioouuss iinnjjuurryy..
DDiissccoonnnneecctt aallll eelleeccttrriicc ppoowweerr,, iinncclluuddiinngg rreemmoottee
ddiissccoonnnneeccttss aanndd ddiisscchhaarrggee aallll mmoottoorr ssttaarrtt//rruunn
ccaappaacciittoorrss bbeeffoorree sseerrvviicciinngg.. FFoollllooww pprrooppeerr
lloocckkoouutt// ttaaggoouutt pprroocceedduurreess ttoo eennssuurree tthhee ppoowweerr
ccaannnnoott bbee iinnaaddvveerrtteennttllyy eenneerrggiizzeedd.. VVeerriiffyy wwiitthh aa
CCAATT IIIIII oorr IIVV vvoollttmmeetteerr rraatteedd ppeerr NNFFPPAA 7700EE tthhaatt aallll
ccaappaacciittoorrss hhaavvee ddiisscchhaarrggeedd..
FFoorr aaddddiittiioonnaall iinnffoorrmmaattiioonn rreeggaarrddiinngg tthhee ssaaffee
ddiisscchhaarrggee ooff ccaappaacciittoorrss,, sseeee PPRROODD--SSVVBB0066**--EENN..
NNOOTTIICCEE
CCooiill DDaammaaggee!!
FFaaiilluurree ttoo ffoollllooww iinnssttrruuccttiioonnss bbeellooww ccoouulldd rreessuulltt iinn
ccooiill ddaammaaggee..
DDoo nnoott cclleeaann tthhee rreeffrriiggeerraanntt ccooiill wwiitthh hhoott wwaatteerr oorr
sstteeaamm aass iitt ccoouulldd ccaauussee hhiigghh pprreessssuurree iinnssiiddee tthhee
ccooiill ttuubbiinngg..
DDoo nnoott uussee aacciiddiicc cchheemmiiccaall ccooiill cclleeaanneerrss.. AAllssoo,, ddoo
nnoott uussee aallkkaalliinnee cchheemmiiccaall ccooiill cclleeaanneerrss wwiitthh aa ppHH
vvaalluuee ggrreeaatteerr tthheenn 88..55 ((aafftteerr mmiixxiinngg)) wwiitthhoouutt uussiinngg
aann aalluummiinnuumm ccoorrrroossiioonn iinnhhiibbiittoorr iinn tthhee cclleeaanniinngg
ssoolluuttiioonn..
• Keep coils clean to maintain maximum
performance. For operation at its highest efficiency,
clean the refrigerant coil often during periods of
high cooling demand or when dirty conditions
prevail. Clean the coil a minimum of once per year
to prevent dirt buildup in the coil fins, where it may
not be visible.
• Remove large debris from the coils and straighten
fins before cleaning. Remove filters before
cleaning.
• Clean refrigerant coils with cold water and
detergent, or with one of the commercially
available chemical coil cleaners. Rinse coils
thoroughly after cleaning.
• Economizer and evaporator coils are installed so
the evaporator is directly behind the economizer.
To clean between the coils, remove the sheet metal
block off. Access the block off by removing the
corner panels on the left or right rear side of the
unit.
• If the refrigerant coil is installed back to back with
the waterside economizer coil, use a cleaner that is
acceptable for cleaning both types of coils.
Inspecting and Cleaning Coils
Coils become externally fouled as a result of normal
operation. Coil surface dirt reduces heat transfer ability
and can cause comfort problems, increased airflow
resistance and thus increased operating energy costs.
Inspect coils at least every six months or more
frequently as dictated by operating experience.
Cleaning frequently is dependent upon system
operating hours, filter maintenance, efficiency, and dirt
load. Following is the suggested method for cleaning
steam and hot water coils.
Steam and Hot Water Coils
WWAARRNNIINNGG
HHaazzaarrddoouuss VVoollttaaggee ww//CCaappaacciittoorrss!!
FFaaiilluurree ttoo ddiissccoonnnneecctt ppoowweerr aanndd ddiisscchhaarrggee
ccaappaacciittoorrss bbeeffoorree sseerrvviicciinngg ccoouulldd rreessuulltt iinn ddeeaatthh oorr
sseerriioouuss iinnjjuurryy..
DDiissccoonnnneecctt aallll eelleeccttrriicc ppoowweerr,, iinncclluuddiinngg rreemmoottee
ddiissccoonnnneeccttss aanndd ddiisscchhaarrggee aallll mmoottoorr ssttaarrtt//rruunn
ccaappaacciittoorrss bbeeffoorree sseerrvviicciinngg.. FFoollllooww pprrooppeerr
lloocckkoouutt// ttaaggoouutt pprroocceedduurreess ttoo eennssuurree tthhee ppoowweerr
ccaannnnoott bbee iinnaaddvveerrtteennttllyy eenneerrggiizzeedd.. VVeerriiffyy wwiitthh aa
CCAATT IIIIII oorr IIVV vvoollttmmeetteerr rraatteedd ppeerr NNFFPPAA 7700EE tthhaatt aallll
ccaappaacciittoorrss hhaavvee ddiisscchhaarrggeedd..
FFoorr aaddddiittiioonnaall iinnffoorrmmaattiioonn rreeggaarrddiinngg tthhee ssaaffee
ddiisscchhaarrggee ooff ccaappaacciittoorrss,, sseeee PPRROODD--SSVVBB0066**--EENN..
1. Disconnect all electrical power to the unit.
2. Wear appropriate personal protective equipment
(PPE).
3. Access both sides of the coil section.
4. Use a soft brush to remove loose debris from both
sides of the coil.
5. Use a steam cleaning machine, starting from the
top of the coil and working downward. Clean the
leaving air side of the coil first, then the entering air
side. Use a block-off to prevent steam from blowing
through the coil and into a dry section of the unit.
6. Repeat step 5 as necessary. Confirm that the drain
line is open following completion of the cleaning
process.
7. Allow the unit to dry thoroughly before putting the
MMaaiinntteennaannccee

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane IntelliPak SCWF 90 and is the answer not in the manual?

Trane IntelliPak SCWF 90 Specifications

General IconGeneral
BrandTrane
ModelIntelliPak SCWF 90
CategoryAir Conditioner
LanguageEnglish

Related product manuals