10
S8V2-SVX001-1A-EN
Model
S8V2C080M5PC
(a)
S8V2C080M5PD
(a)
S8V2C100M5PC
(a)
S8V2C100M5PD
(a)
S8V2D120M5PC
(a)
S8V2D120M5PD
(a)
Type Upflow / Horizontal / Downflow Upflow / Horizontal / Downflow
Upflow / Horizontal /
Downflow
RATINGS
(b)
1st Stage Input BTUH 52,000 65,000 84,000
1st Stage Capacity BTUH (ICS) 41,800 52,300 67,900
2nd Stage Input BTUH 80,000 100,000 120,000
2nd Stage Capacity BTUH (ICS)
(c)
64,800 81,200 98,000
1st Stage Temp. Rise (Min. - Max.) °F
30 - 60 25 - 55 30 - 60
2nd Stage Temp. Rise (Min. - Max.) °F
30 - 60 30 - 60 35 - 65
AFUE – Rating
(c)
80 80 80
Return Air Temp. (Min. - Max.) °F
55°F - 80°F 55°F - 80°F 55°F - 80°F
BLOWER DRIVE DIRECT DIRECT DIRECT
Diameter - Width (in.)
11 X 11 11 X 11 11 X 11
No. Used 1 1 1
Speeds (No.)
(d)
Variable Variable Variable
CFM vs. in. w.g.
See Fan Performance Table See Fan Performance Table See Fan Performance Table
Motor HP 1 1 1
R.P.M. Variable Variable Variable
Volts / Ph / Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
FLA 10 10 10
COMBUSTION FAN - Type
PSC PSC PSC
Drive - No. Speeds
Direct - 2 Direct - 2 Direct - 2
Motor HP - RPM
3300/2700 3200/2900 3200/2900
Volts/Ph/Hz 120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
FLA 0.30 0.33 0.33
Inducer Orifice 1.80 2.50 2.15
FILTER - Furnished? No No No
Type Recommended High Velocity High Velocity High Velocity
Hi Vel. (No.-Size-Thk.)
1 - 20 X 25 - 1 in. 1 - 20 X 25 - 1 in. 1 - 24 X 25 - 1 in.
VENT PIPE DIAMETER - Min. (in.)
4 Round 4 Round 4 Round
HEAT EXCHANGER - Type
Aluminized Steel Aluminized Steel Aluminized Steel
Gauge (Fired)
20 - 19 20 - 19 20 - 19
ORIFICES - Main
Nat. Gas Qty. - Drill Size
4 - 45 5 - 45 6 - 45
L.P. Gas Qty. - Drill Size
4 - 56 5 - 56 6 - 56
GAS VALVE
Redundant - Two Stage Redundant - Two Stage Redundant - Two Stage
PILOT SAFETY DEVICE - Type 120 V SiNi Igniter 120 V SiNi Igniter 120 V SiNi Igniter
BURNERS - QTY
4 5 6
POWER CONN. - V/Ph/HZ
(e)
120 / 1 / 60 120 / 1 / 60 120 / 1 / 60
Ampacity (Amps)
13 13 13
Max. Overcurrent Protection (Amps)
15 15 15
PIPE CONN. SIZE (IN.)
1/2 1/2 1/2
(a)
Central Furnace heating designs are certified to ANSI Z21.47 - latest edition.
(b)
For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level.
(c)
Based on U.S. government standard tests.
(d)
Direct drive variable speed blower motor is an ECM constant airflow blower motor.
(e)
The above wiring specifications are in accordance with National Electric Code, however, installations must comply with local codes.
PPrroodduucctt SSppeecciiffiiccaattiioonn