EasyManuals Logo
Home>Truper>Portable Generator>GEN-55X

Truper GEN-55X User Manual

Truper GEN-55X
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
12
ENGLISH
Troubleshooting
If problems persist despite taking recommended corrective actions,
contact a Authorized Service Center
Problem Cause Solution
• The switch is OFF.
• Not enough fuel.
• Devices connected to the generator.
• Gasoline does not reach the carburetor.
• There is no spark in the spark plug.
• The oil level is too low.
• The overload protector has not been
reestablished.
• Some of the devices connected are not
working.
• Damaged overload protection.
• The transportation protection has not been
removed.
The motor is not
starting.
The motor starts but
stops unexpectedly.
There is no current in
the connection panel
outlets.
The generator has no
voltage.
The generator vibrates
or makes too much
noise.
• Turn the switch ON.
• Fill the fuel tank.
• Disconnect all devices from the connection
panel before starting the generator motor.
• Having the fuel tank full, verify the fuel flow to
the carburetor:
1. Set under the carburetor, an adequate
container to receive gasoline. Use a funnel to
prevent spilling the fuel.
2. Remove the drain bolt. Fuel shall flow freely.
Otherwise, go to a
Authorized Service Center.
• Verify spark in the spark plug:
1. Disconnect the spark plug cable. Clean the
dust around the spark plug and remove it.
2. Connect the cable to the spark plug.
3. Turn ON the motor switch.
4. Make contact with the lateral electrode of the
spark plug with any metallic part of the motor
that is free of oil. It is important
to carry out the test in a well-ventilated area and
with no fuel spilled. Otherwise it could cause an
explosion.
5. Pull the jack-line to generate a spark in the
space between the spark plug center electrode
and the lateral electrode.
6. If there is no spark with the new spark plug, go
to a Authorized Service
Center.
• Check oil level in the motor as indicated in
page 7. Start the motor one more time.
• Verify the thermal protection is ON.
• Check the status of the devices before
connecting. Repair any damaged device before
using it with the generator.
• Go to a Authorized Service
Center to replace it.
• Remove the transportation support before
operating the generator as indicated in page 8.
The support is identified with a label mentioning:
“Remove this protection before using the
generator”.
CAUTION

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Truper GEN-55X and is the answer not in the manual?

Truper GEN-55X Specifications

General IconGeneral
BrandTruper
ModelGEN-55X
CategoryPortable Generator
LanguageEnglish

Related product manuals