Maintenance
E
C
B
ENGLISH
Start up
1. If the generator is operating in very dusty environments, carry out maintenance more frequently.
2. Go to a Authorized Service Center to carry out this service.
• In high altitudes, the amount of fuel in the carburetor mix
increase, performance is lower and fuel consumption is
higher.
• Even though the carburetor injection is adequate, the
motor power is lower by 3.5% per each 1000 feet above
6890 feet above sea level. The decrease in power will be
more drastic if no adjustments to the carburetor are carried
out. Consult a Authorized Service
Center to make the adjustments.
Operating in High Altitude
• Regular and careful maintenance es
essential to keep the generator optimal security and
performance levels.
• Before cleaning, repairing, inspecting or storing the
generator, turn OFF the motor and wait until the motor
has completely cooled down.
• Keep all the nuts, bolts and screws adjusted to assure
the generator is in a safe working condition.
CAUTION
• Do not modify the safety devices. Verify regularly to
ensure proper operation.
• Any worn or damaged part shall be replaced before
using the generator. Do not try to repair parts. The
generator can get damaged and put your safety at risk.
• Any repairs or maintenance different to those described
in this section, for example, adjusting the carburetor, shall
only be carried out in a Authorized
Service Center.
• Turn OFF the heat protector (B).
• Close the fuel tap (C).
• Set the switch (E) into the OFF position.
• Disconnect all the devices from the connection panel.
• If during an emergency, the generator has
to be turned off quickly, you can do it in one step setting the
switch (E) into the OFF position.
Turning OFF
CAUTION
Before each
use
Check Replace
ReplaceClean (1)
Clean
Clean
Clean
Make
Check
Check and replace each 3 years if necessary (2)
Clean / readjust
Check / readjust (2) Check / readjust (2)
Clean (2)
Each 25 h
of use
Each 50 h
of use
Each 300 h
of use
Each 100 h
of use
Periodic
Maintenance
General maintenance
Motor Oil
Air filter
Sediment container
Spark Plug
Valve clearance
Fuel tank and Sieve
Fuel line
Oil filter
Fuel tank cap