E. Continuity Test
Range Resolution
0.1
Accuracy
Around 30,the
buzzer beeps.
(Open circuit voltage
approx. –1.2V)
Overload protection
250VAC
Remark:
The buzzer may or may not beeps when the resistance of a circuit under test is
between 30~100Ω.
The buzzer does not beep when the resistance of a circuit under test is > 100
Model UT207/208: OPERATING MANUAL
43

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT207 and is the answer not in the manual?

UNI-T UT207 Specifications

General IconGeneral
BacklightYes
AC current range66 - 1000 A
DC voltage range6.6 - 600 V
Resistance range20 - 20000 Ω
Basic accuracy (frequency)±(0.1%+3)
Basic accuracy (DC current)±(1.5%+8)
Basic accuracy (DC voltage)±(0.8%+1)
Basic accuracy (resistance)±(1%+2)
Temperature measurement range-40 - 1000 °C
Dimensions (WxDxH)105 x 45 x 286 mm
Battery voltage9 V