34
Model UT231: OPERATING MANUAL
B. Replacing the Battery (see figure 11)
Warning
To avoid false readings, which could lead to possible
electric shock or personal injury, replace the battery
as soon as the battery indicator “ ” appears.
Make sure the transformer jaw and the tests leads
are disconected from the circuit being tested before
opening the case bottom.
To replace the battery:.
Press POWER to turn the Meter off and remove all
the connections from the input terminals
Turn the Meter’s front case down.
Remove the screw from the battery door, and separate
the battery door from the case bottom.
Take out the old battery and replace with 4 x 1.5V
battery (LR6).
Rejoin the case bottom and the battery compartment,
and reinstall the screw.
1.
2.
3.
4.
5.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT231 and is the answer not in the manual?

UNI-T UT231 Specifications

General IconGeneral
BacklightYes
Product typeDigital multimeter
Frequency range0.02 - 0.5 kHz
AC current range40 - 1000 A
AC voltage range15 - 600 V
Temperature measurement range-50 - 1000 °C
Dimensions (WxDxH)112 x 39 x 303 mm
Battery voltage1.5 V
Weight and Dimensions IconWeight and Dimensions
Weight601 g