45
Model UT71A/B/C/D/E: OPERATING MANUAL
J. Power Measurement (UT71E only)
Warning
To avoid damages to the Meter, please do not attempt
to input higher than 250V from outlet altogether reading
may be obtained.
Take extra care during measurement to avoid electric
shock.
Switch off the power before the Meter and the object
being measured connect to the circuit.
Set the rotary switch to W.
Insert the power adaptor to the corresponding input
terminals, and plug the power adaptor to the outlet.
Insert the object to be measured into the outlet of
the power adaptor.
The measured value shows on the display. The
primary display shows the power value, the left
secondary display show the power factor value and
right secondary display shows the apparent power
value.
1.
2.
3.
4.
Figure 3-9. Power Measurement
To measure power, proceed the following:

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the UNI-T UT71E and is the answer not in the manual?

UNI-T UT71E Specifications

General IconGeneral
Data holdYes
Product typeDigital multimeter
Frequency range0.04 - 40000 kHz
AC current range0.4 - 10 A
AC voltage range4 - 1000 V
DC voltage range0.4 - 1000 V
Capacitance range40 - 40000 nF
Statistic functionMaximum, Minimum
Basic accuracy (frequency)0.01%+8
Basic accuracy (DC current)0.08%+8
Basic accuracy (DC voltage)0.025%+5
Basic accuracy (resistance)0.3%+8
Basic accuracy (capacitance)1%+20
Temperature measurement range-40 - 1000 °C
Dimensions (WxDxH)93 x 40 x 200 mm
Battery voltage9 V
Weight and Dimensions IconWeight and Dimensions
Weight384 g