Page #56 background imageLoading...
Page #56 background image
UTD2000 Series User Manual
56
Measuring one step voltage of the step signal
To measure one step voltage of the step signal, follow the steps below:
1. Press CURSOR to display the cursor measurement menu.
2. Press menu operation key F1 to set cursor type to VOLTAGE.
3. Turn the multifunction control knob to set cursor 1 at one step voltage of the step signal.
4. Press SELECT to select the cursor, then turn the multifunction control knob again to set
cursor 2 at another step voltage of the step signal.
The cursor menu will automatically display the V value, i.e. the voltage difference of that
point. See the figure below.
Figure 12-6 Measure the voltage difference of signals by cursors
Note: When using the cursors to measure time, follow step 2 only and set the cursor type
to time.