UTL8500 Series User Manual
45
Set the Start Time of Delay
Set the Time for Short Circuit
Test
Set the Voltage Value of Over-
Voltage Protection
Set the Current Value of Over-
Current Protection
Set the Power Value of Over-
Power Protection
Set the Load Voltage at the
Beginning of Each Run
Set the Low Voltage to
Automatically End Loading
Set the Self-Start Voltage of
the List Mode
Set whether to Enable the
Overvoltage Protection
Function
Set the Level of Digital Filter
Set the Role of External
Trigger Signal Input (Function
Multiplexing)
5.2.1 Run Time
If you set the single load time of the electronic load, no matter what mode it is running in,
the load will automatically stop loading after the set timing is reached. When this function
is not needed, set the parameter to 0.
5.2.2 Delay On
If you set the delay before the electronic load is loaded each time, no matter what mode it
is running, when the ON button is pressed, the electronic load will wait for the set delay
time and then start loading.
5.2.3 V Trigger
V Trigger is the voltage value of automatically-started loading after setting the list mode.
After setting the self-start voltage, enter the list mode without pressing the ON key to enable
the load. When the input voltage of the electronic load exceeds the set self-start voltage,
the list mode will automatically start.