10.2 PROBLEMS IN CONNECTION WITH THE LEVEL REGULATION
10.2a The steam boiler is flooded
The steam boiler is flooded

Problem generated by the Problem generated by the
filling valve water level probe

* The filling valve flap is no
longer in place and generates
leaks: fur or any other obstacle...
The probe is covered with an
insulating agent (scale) or the
probe wire is cut out
* The filling valve relay got stuck
Clean probes and check
cables
* Replace gaskets and clean the
filling valve surface
* Replace the electric valve or the
leval box, as necessary.
10.2b The boiler is empty
RISK TO RUIN THE HEATING ELEMENT
The probe is
directly earthed
The filling valve is not ON
or its coil is burnt out

Check:
- the probe wire
- the valve cable
- the electronic box functioning
- the valve
Replace as necessary
Check the state of the heating element