42
Part. 14000001 Rev. 04//2021
®/™ ©2021 Unity Laundry Systems. All rights reserved.
COIN MECHANISM - VENDED MODEL ONLY
13.3 MENU SETTINGS
INDICATION DESCRIPTION (STEP 2) (STEP 3) (STEP 4)
tH Teaching Mode
Select Channel: From c1
to c12
Set Coin Value: Min 0, Max
255
Insert 6 coins: 00 to 05 (Blink
indicates setting is
Pr Price Set Price: Default : 1 Min 0 , Max 255
Cn Coin Value
Select Intended Channel
(c1 to c7)
Set New Coin Value Min 0,
Max 255
tL
Coin / Token
Acceptance Toler-
ance Number
Select Channel number
from c1 to c12 to adjust
the tolerance
Select Tolerance: t1 and t2:
Diameter t3 to t6 : Material
Default: 08 Min 0, Max
15 Higher Number: Wider
Tolerance Lower Number:
Narrower Tolerance
dL Delete
Select Intended Channel
(e.g., c6)
Enable Channel : 00 Delete
Channel : 01
In
To Enable Inhibit
Mode
No Inhibition
: no Low Inhibition :Lo High
Inhibition : HI
13.4 EXAMPLE OF SETTING / TEACHING 50 CENTS TO CHANNEL 2
To set 50 cents on Channel 2 (c2):
1. Enter the setting mode.
2. Select“tH”fromthemenuandpress“Ent”toconrm.
3. Thedisplaywillshow“c1.”Use“+”tolookfor“c2”andpress“Ent”toconrm.
4. Theoriginalcoinvaluewillappearonthedisplay.Keeppressing“+/-”andstopatcoinvalue“5.”Press“Ent”toconrm.
5. The display will show “00” with blinking. Insert 6 pieces of 50 cents coin. The menu will automatically return to “c2.” (use
multiple 50 cents coins to maximize the coin acceptance rate)
6. Press “Esc” for more than 2 seconds to exit and press “Esc” again for more than 2 seconds to return to the setting mode.
13.5 EXAMPLE OF CHANGING THE PRICE
To change price from 1 (default value) to 5:
1. Enter the setting mode.
2. Navigateto“Pr”byusing“+/-”andpress“Ent”toconrm.
3. The original price “1” will appear on the display, use “+” to search for “5” and stop.
4. Press“Ent”toconrm.Themenuwillreturnto“Pr.”
5. Press “Esc” for more than 2 seconds to save to exit.
Note: Changing the price value will affect the coin slot pulse output. Refer to “Understanding Coin Value/ Price Vs
Pulse Output” for more information.