EasyManuals Logo
Home>Uwatec>Diving Instrument>Smart 2

Uwatec Smart 2 User Manual

Uwatec Smart 2
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #17 background imageLoading...
Page #17 background image
17
2 Attention messages and alarms
UWATEC
®
Smart dive computers
Smart Z draws the diver’s attention to certain situations and warns the diver of unsafe diving practices.
Attention messages and alarms are always visual and audible under water, only visual at the surface except
the decompression alarm.
The audible attention messages (but not the alarms) can be selectively
switched
off with SmartTRAK.
III
English
2.1 Attention messages
Attention messages are communicated to the
diver visually by symbols, letters or flashing figu-
res. In addition, two short audible sequences can
be heard (in an interval of 4 seconds) in two diffe-
r
ent frequencies under water.
Attention messages come up in the following
situations (more information can be found on the
listed pages):
Page
Maximum Operating Depth / max ppO
2
is reached 20
Set maximum depth is reached 19
Oxygen toxicity
reaches 75% 21
No-stop time = 2 minutes 22
Prohibited altitude* (surface mode) 25
Entering decompression when diving with L0
23
Remaining Bottom Time < 3 minutes 22
Tank pressure has reached set warning level 21
Increased workload 21
Diving with microbubble levels (L1-L5):
MB no-stop time = 0 30
MB level stop ignored 31
MB level reduced 31
Entering decompression when diving
with MB level L1-L5 31
*without audible attention beep
4 sec
2.2 Alarms
Serious injury or death may result from failing to
immediately respond to alarms given by Smart Z.
Alarms are given to the diver visually by flashing
symbols, letters or figures. In addition, an audible
sequence in one frequency can be heard during
the whole duration of the alarm.
An alarm occurs in the following situations (more
information can be found on the listed pages):
Page
Oxygen toxicity reaches 100% 21
Ignored decompression 23
Remaining Bottom Time = 0 22
Exceeding the prescribed ascent rate 20
(Particular scale of beeps, ->20)
Low battery alarm**
see below
Low battery alarm Smart Z**
The service symbol appears if the battery capacity
reaches 0%.
Take the unit to your
authorised SCUBAPRO
UWATEC retailer.
Transmitter battery low: **
"bAt"
flashing and alternating with the display of
the tank pressure.
Replace the battery in
the transmitter ->36.
**without audible alarm
(can be switched off)
(can not be switched off)
WARNING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Uwatec Smart 2 and is the answer not in the manual?

Uwatec Smart 2 Specifications

General IconGeneral
BrandUwatec
ModelSmart 2
CategoryDiving Instrument
LanguageEnglish

Related product manuals