0020244064_02 Operating and installation instructions 13
Appendix
A Pressure loss curve
20
0
40
60
80
100
120
140
102345
6
A
B
A Volume flow: [m
3
/h]
B Pressure loss Δp: [mbar]
B Technical data
Technical data
VPS R 100/1 M VPS R 200/1 B
Nominal capacity
101 l 202 l
Outer diameter of the cylinder
550 mm 600 mm
Height of the cylinder
932 mm 1,202 mm
Net weight
34 kg 44 kg
Weight when filled with water
135 kg 246 kg
Material of the cylinder and the connections
Steel Steel
Water pressure range
0.1 to 0.3 MPa
(1.0 to 3.0 bar)
0.1 to 0.3 MPa
(1.0 to 3.0 bar)
Maximum operating temperature
95 95
Diameter of the water connections
G1" 1/2 G1" 1/2
Diameter of the sensor pocket
G1/2 G1/2
Maximum volume flow
6 m³/h 6 m³/h