Auxiliary functions
20 Operating instructions ecoTEC plus 0020134822_01
6
5.6 Service message
58
5.4 Service message
If the open-ended spanner is displayed, the boiler requires a
service.
> Consult your competent person about doing this.
The boiler is not in fault mode but continues to operate.
> In the "Live monitor", you can read further information
about the reason for the service (¬section 6.2).
> If your boiler shows that it is working in the Comfort
safety mode, contact your approved competent person.
> Inform the approved competent person of the status
code that is displayed.
i
If the water pressure is shown flashing at the
same time (¬section5.4), you only have to top
up the water (¬section4.6.3 and 4.6.4).
5.7 Resolving faults in the air/flue gas duct
a
Danger!
Risk of injury and material damage
resulting from improper modifications!
Improper modifications can affect the oper-
ating safety of your boiler.
> Never attempt to perform repairs on
your boiler by yourself.
> Always employ a competent person.
The boilers are fitted with a fan. If the fan does not work
properly, the boiler will switch itself off.
The fault message "F.32" appears in the display. The dis-
played fault code is additionally explained by a correspond-
ing plain text message in the display: "Fault: Fan".
6 Auxiliary functions
The digital information and analysis system provides you
with further functions via the menu.
6.1 Operation in the menu
You can access this menu by pressing both selector buttons
("i") at the same time.
6.1.1 Structure of the menu
In addition to the direct operation via the selector buttons
from the basic display menu, the digital information and
analysis system has a menu that, in turn, has two selection
levels (sublevels).
Through the selection levels, you navigate to the display
and setting levels in which you can read or change settings.
The selection levels have four display fields.
Menu
Water pressure
Live Monitor
Information
Back Select
1
4
2
3
6.1 Display fields in the menu
Key
1 Scroll bar (only if there are more list entries than can be shown
at once on the display)
2 Current functions of the right and left-hand selector buttons
(soft key functions)
3 List entries for the selection levels
4 Name of the selection level
i
In the following, path details at the beginning of
an instruction specify how to access this func-
tion, e.g. Menu ¬Information ¬Contact data.