Troubleshooting
21
Vanderbilt International (IRL) Ltd.
14 Troubleshooting
Lock does not open when Group code/PIN is
entered.
Check that the correct Group code/PIN has
been entered.
Make sure the handle is not pressed down as
the code is entered
Check that the handle is not sagging.
Check that CD30 is fitted exactly vertical.
Check that the lock is not fitted too tightly to the
door, in which case the handle could be
jammed.
Check that the red mark on the follower for
the lever handle spindle is pointing
CD30 is in unlocked position Set CD30 to locked position (if required). See
section 10.2 Lock/unlock door.
CD30 does not sound following key presses. Activate the buzzer. See section
10.3 Disable/enable buzzer.
Check the batteries and change any discharged
batteries. See section 9.3 Change batteries.
Batteries are rapidly discharged. Frequent use requires frequent change of
batteries. See section 9.3 Change batteries.