4.3
ELECTRICAL
CONNECTION
Prior to connecting the
machine to the electrical
mains, assess that the
voltage shown on the
machine’s data plate
corresponds with that of the
mains.
4.2
WATER
CONNECTION
Avoid throttling in the
connecting tubes. Assess
that the drain pipe is able
to eliminate waste. It is
forbidden to use connecting
pipes already used in the
past. Filter maintenance
is the responsibility of the
purchaser.
1 Mesh filter
2 Softener
3 Drain 50 mm
Failing to maintain water into
the correct levels will void the
warranty.
1
2
3
WATER SPECIFICATIONS
• Total hardness 50-60 ppm
(parts per million).
• Water line pressure
between 2 - 5 bar and
water to be cold.
• Min flow rate: 200 l/hr.
• Filtration level below 1.0
micron.
• tds (total dissolved solids)
level between 50 – 250
ppm.
• Alkalinity level between 10
– 150 ppm.
• Chlorine level less than
0.50 mg/l.
• ph level between 6.0 - 8.0.
ELECTRICAL
SPECIFICATIONS
230V - monophase voltage