2 D-302893
WIRELESS
Frequency Band (MHz): Europe: 433, 868, USA: 915
Communication Protocol: PowerG
Supervision: Signaling at 4-min. intervals
Tamper Alert: Reported when a tamper event occurs and in any
subsequent message, until the tamper switch is restored
MOUNTING
Height: 1.8 - 2.4 m (6 - 8 ft). For Next CAM-K9 PG2, the
recommended height is up to 2.1 m (7 ft)
Installation Options: Surface or corner
ACCESSORIES
BR-1: Surface mounted swivel bracket, adjustable 30° down and
45° left/45° right.
BR-2: BR-1 with a corner adapter
BR-3: BR-1 with a ceiling adapter
ENVIRONMENTAL
RFI Protection: >20 V/m up to 2000 MHz, excluding inband
frequencies
Operating Temperatures: -10
°C to 50°C (14°F to 122°F) indoor
Storage Temperatures: -20
°C to 60°C (-4°F to 140°F).
Humidity: Average relative humidity of approximate up to 75%
non-condensing. For 30 days per year relative humidity may vary
between 85 % and 95 % non-condensing.
Compliance with Standards:
USA: Designed to meet FCC Part 15
Europe: Directive 1999/5/EC of the European Parliament. EN
50131-1 Grade 2 Class II. EN 50131-2-2, EN 50131-6
PHYSICAL
Size (H x W x D): 125 x 63 x 60 mm (4-15/16 x 2-1/2 x 2-3/8”).
Weight (with battery): 200 g (7 oz).
Color: White
PATENTS
U.S. Patents 5,693,943 z 6,211,522 z D445,709 (another patent
pending)
3. ENROLLMENT
Refer to the control panel Installer Guide for the device enrollment procedure.
4. Next CAM PG2 / Next CAM-K9 PG2 DEVICE SETTINGS
This section describes how to configure the parameters of the PIR detector from the control panel.
To Modify the PIR Detector Device Settings
Refer to the control panel Installer Guide and perform the procedure for Adding A Wireless Device (section 4.5.2), or, Modifying a Device
(section 4.5.5). Then continue below to modify the device settings.
1.
Here you determine whether or not the alarm LED indication will be activated.
2.
3.
or
Select between "LED ON" and "LED OFF".
4.
5.
Here you determine whether an alarm will be activated upon continued motion (low
sensitivity) or upon a single alarm event (high sensitivity).
6.
7.
or
Select between "LOW sensitive" and "HIGH sensitive".
8.
9.
Here you set the activity time during disarm.
10.
11.
or
Select between "NOT Active", "YES – no delay", "YES + 5s delay", "YES + 15s
delay", "YES + 30s delay", "YES + 1m delay", "YES + 2m delay", "YES + 5m delay",
"YES + 10m delay", "YES + 20m delay" and "YES + 60m delay".
12.