Cooling System
D5A T HE, D5A T KC, D5A T RC, D5A TA HE, D5A
TA KC
Cooling system
Type Designation D5A T HE/D5A TA HE D5A T RC D5A T KC/D5A TA KC
Freshwater system capacity
including heat exchanger,
approx.
22 liters (5,8 US gals) 32 litres (8,5 US gals) 11 liters (2,9 US gals)
Coolant temp normal operation 85 - 95 °C (185 - 203 °F) 85 - 95 °C (185 - 203 °F) 83 - 95 °C (181 - 203 °F)
Shutdown point High coolant
temp.
103 °C (217 °F) 103 °C (217 °F) 103 °C (217 °F)
D7A T HE, D7A T KC, D7A T RC, D7A TA HE, D7A
TA KC
Cooling system
Type Designation D7A T HE/D7A TA HE D7A T RC D7A T KC/D7A TA KC
Freshwater system capacity
including heat exchanger,
approx.
22 liters (5,8 US gals) 40 litres (8,8 US gals) 14 liters (3,7 US gals)
Coolant temp normal operation 83 - 95 °C (181 - 203 °F) 83 - 95 °C (1815 - 203
°F)
83 - 95 °C (181 - 203 °F)
Shutdown point High coolant
temp.
105° ± 0,5°C (221° ±
1°F)
105° ± 0,5°C (221° ±
1°F)
105° ± 0,5°C (221° ±
1°F)
Technical Data
104 47713337 03-2021 © AB VOLVO PENTA