Technical Data
Engines
D5A T HE, D5A T KC, D5A T RC, D5A TA HE, D5A
TA KC
General
Type Designation D5A T HE
No. of cylinders 4
Displacement
4,76 liters (290 in
3
)
Dry weight
(1)
, engine without generator and frame, approx.
510 kg (1124 lbs)
Valve clearance, setting values (cold engine)
Inlet 0,30 mm (0,0118’’)
Exhaust 0,50 mm (0,0197’’)
1) excl. engine oil and coolant
Exhaust temperatures
(1)
77 kW @ 1500 rpm 81 kW @ 1800 rpm
at 25% of ISO Standard Power 210°C (410°F) 205°C (401°F)
at 50% of ISO Standard Power 300°C (572°F) 280°C (536°F)
at 75% of ISO Standard Power 385°C (725°F) 340°C (644°F)
at 100% of ISO Standard Power 455°C (851°F) 385°C (725°F)
at 110% of ISO Standard Power 480°C (896°F) 400°C (752°F)
1) Approximated values, temperatures varies with ambient temperature and back pressure in the exhaust line.
General
Type Designation D5A TA HE
No. of cylinders 4
Displacement
4,76 liters (290 in
3
)
Dry weight
(1)
, engine without generator and frame, approx.
525 kg (1157 lbs)
Valve clearance, setting values (cold engine)
Inlet 0,30 mm (0,0118’’)
Exhaust 0,50 mm (0,0197’’)
1) excl. engine oil and coolant
Exhaust temperatures
(1)
92 kW @ 1500 rpm 100 kW @ 1800 rpm
at 25% of ISO Standard Power 200°C (392°F) 200°C (392°F)
at 50% of ISO Standard Power 290°C (554°F) 280°C (536°F)
at 75% of ISO Standard Power 365°C (689°F) 325°C (617°F)
at 100% of ISO Standard Power 410°C (770°F) 365°C (689°F)
at 110% of ISO Standard Power 435°C (815°F) 380°C (716°F)
1) Approximated values, temperatures varies with ambient temperature and back pressure in the exhaust line.
96 47713337 03-2021 © AB VOLVO PENTA