Recommendation of Daily Operation Records
Items to be recorded
The following items are recommended to be recorded
once a day:
1. Operating hours.
2. The amount of lubrication oil and coolant (fresh
water) required for refilling. Fuel consumption.
3. Lubrication oil and coolant (fresh water) changes.
4. Lubrication oil pressure and temperature, engine
rpm, exhaust temperature, coolant temperature,
and charge air temperature and pressure.
5. Rawwater pressure and rawwater temperature
before and after heat exchanger. Ambient tem-
perature and engine room temperature at turbo
charger inlet.
6. Parts serviced and kinds of service (adjustment,
repairs or replacement).
7. Change in operating conditions (for example, “Ex-
haust smoke turned black, etc.)
Daily recording is a preventive maintenance program and when comparing values with engine history it will help
you recognize conditions, signs or indications of approaching trouble. Daily operation records also make trouble
shooting easier and will lessen the down time (to save time and money for servicing).
57
Maintenance: General

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Volvo Penta D9 MH EVC and is the answer not in the manual?

Volvo Penta D9 MH EVC Specifications

General IconGeneral
BrandVolvo Penta
ModelD9 MH EVC
CategoryEngine
LanguageEnglish

Related product manuals