BPU 2440/2950 Repair Maintenance
wc_tx000328gb.fm 21
4.2 Maintenance Schedule
Daily
before
starting
Every
25
hrs.
Every
100
hrs.
Every
300
hrs.
Check engine oil level.
Visually inspect exciter base for leaks.
Inspect/clean air filter. Re-oil foam element;
replace as required.
Check/tighten external hardware.
Change engine oil.
Inspect/adjust V-belt.
Check/regap spark plug. Replace when
nececessary.
Clean engine cylinder cooling fins.
Inspect shockmounts. Replace if cracked
or split.
Change exciter oil.
Chang hydraulic oil in handle.
Change fuel filter or strainer.
Clean combustion chamber.
Check/adjust breaker point ignitions.
Clean/rinse fuel tank.
Clean rewind starter.
For new or reconditioned engines
:
Check/adjust belt tension. After first 5 hours of operation.
Change engine oil. After first 10 hours of operation.