8 Operation and use
27 100_0202_op_0011.fm
8 Operation and use
8.1 Before commissioning
8.1.1 Inspection before commissioning
Open protective hoods
1. Pull hood opener of rear protective hood until it is unlocked. Completely open protective hood.
2. Pull hood opener of front protective hood until it is unlocked. Completely open protective hood.
Complete the following inspections:
Check machine and components for damage. If there is any visible damage, do not use the machine
and immediately contact the Wacker Neuson service.
Ensure that loose packing material has been removed from the machine.
Ensure that there are no loose items under the protective hood e.g. gloves or tools.
Check fuel level.
Check engine oil level.
Check hydraulic oil level.
Check fuel lines for leaks.
Make sure the screwed connections are firmly in place.
Receiver units are free of dirt.
WARNING
Improper handling can result in injury or serious material damage.
Please read and follow all safety instructions in this operator’s manual.
Item Designation Item Designation
1 Hood opener of rear protective hood 2 Hood opener of front protective hood
NOTE
Perform tests in accordance with maintenance chapter, top up any missing fuel, see
technical data chapter.