10 Troubleshooting
100_0202_ts_0010.fm 54
10.3 Troubleshooting chart – remote control
Pictogram LED under pictogram Possible causes Remedial measure
Control lamp lights red and
the diagnosis control lamp
flashes green.
Joystick is defective. Have joystick replaced. *
Remote control is defective. Have remote control
replaced or repaired. *
Control lamp flashes or lights
up red operation.
Rechargeable battery of the
remote control is discharged.
Load or replace
rechargeable battery of the
remote control.
Operate machine with
charging cable (for
simultaneous loading of the
rechargeable battery).
After switching on the
remote control, the operation
control lamp does not flash.
Rechargeable battery of the
remote control is discharged.
Load or replace
rechargeable battery of the
remote control.
Remote control is defective. Have remote control
replaced or repaired.*
Charging control lamp
flashes green.
The rechargeable battery is
automatically being pre-
warmed for charging.
Charging the battery at
temperatures below 0°C
may not be possible.
Wait until the charging
control lamp is green and
charging begins.
Rechargeable battery at
temperatures above 0°C.
Remote control switches itself off – if no button on the remote control is pressed, the remote control will
automatically switch off after 10 minutes.
*
Have this work done by the service of Wacker Neuson.