EH 23, 27 Maintenance
31
8 Maintenance
8.1 Maintenance schedule
WARNING
Improper handling can result in injury or serious material damage.
f Read and follow all safety instructions of this operator's manual, see chapter
Safety.
Task Daily be-
fore oper-
ation
Every
20 hrs.
Monthly
Check power cable for perfect
condition – if power cable is
defective, have it replaced. *
* Have these tasks carried out by the service department of your Wacker
Neuson contact person.
Visual inspection of all parts
for damage.
Clean the machine.
Keep ventilation slots on the
laterial protective cover free
from dirt – clean if required.
Check shanks and cutting
edges of tool – sharpen, re-
forge or replace as needed.
Lubricate motor head via the
zerk fittings.
Lubricate the machine.
Check tool holder for wear –
have it changed, if necessary.
*