VM
3.0 TECHNICAL INFORMATION
2
TOR.VM.--.M.A.0518.EN Issue: A
05.18
11
Technical data and codes
Control unit
Code Description
Operation
temperature
Case Power Pressure switch
VMX01N
Control Unit (without
solenoid valve)
-10°C +40°C
Polymer
IP55
N.O+N.C
Max.230 VAC 0.5 A (Inductive)
Max.24 VDC 4A (Resistive)
T-6740010020 24 VAC solenoid valve
-10°C +40°C IP65
5.5 VA
Rod diameter: 9 mm
Format: DIN 43650 (22mm)
Connector included
6740010060 115 VAC solenoid valve 5.5 VA
T-6740010080 230 VAC solenoid valve 5.5 VA
T-6740010030 24 VDC solenoid valve 6 W
3.2.2 Accessories: Control Unit VMX
The control unit VMX allows:
- drive the opening / closing of the VM valve
- adjust the control pressure
- detect the presence of the control pressure on the valve
Important
On ordering the control unit, it is necessary to also require the solenoid valve, by specifying the code
on the basis of the supply voltage.
Pressure
regulator
AIR OUT
(VM)
Coil
Pressure
switch
AIR IN
(Line)