5.0 INSTALLATION AND FIXING
VM
2
TOR.VM.--.M.A.0518.EN Issue: A
05.18
19
5.3 Electrical connection of the control unit VMX
1
2
3
4
5
L
N
GND
N.A
N.C
COM
AIR IN
3..8 bar
Ø8x1
Ø8x1
AIR OUT
Pc = 0..6 bar
3 x 1.5
3 x 1.5
Item Description
1 Pressure gauge
2 Pressure regulator
3 Monostable solenoid valve 3/2 1/8” N.A
4 Pressure switch 1/8" 2.5 bar
5 Solenoid valve