Return Air Filters
Check the return air filter about once a month and clean as necessary. To clean the filter, remove it from the unit,
rinse with water, air dry and reinstall. (Do not used compressed air)
Winterization
There are several methods of winterization, some of which work better than others. There are various methods
employed using a 50/50 non-polluting biodegradable anti-freeze/water solution. Any method that causes the
anti-freeze solution to flow downward is the method of choice. By this, the anti-freeze solution will displace any
water trapped and eliminate the possibility of freezing in hidden areas. In addition, since the seawater pump utilizes
a magnetically driven impeller, the impeller should be removed from the wet end assembly, Wiped with a solution,
and stored in a warm, dry area until commissioning takes place.
Collect all discharged liquids and recycle or dispose of in a proper manner.
Unit Dimensions & Technical Specifications