AC
or
Self-Contained
Battery
Power
The
Welch
Allyn
Spot
Vital
Signs
can
be
made
available
in
many
convenient
locations,
for
a
variety
of
spot-check
needs.
Blood Pressure
A
single
blood
pressure
determination
is
made when
the
Blood
Pressure
Start/
je
Stop
button
is
pushed.
(A,
i
To
cancel
a
measurement
cycle
at
any
time,
press
the
Blood
Pressure
Start/Stop
button
again.
This
action
immediately
initiates
a
rapid
cuff
deflation.
The
blood
pressure
measurement
data
appears
on
the
display
immediately
following
the
measurement
and
remains
displayed
for
2
minutes.
After
2
minutes,
the
display
goes
blank
and
the
device
goes
into
Standby
Mode.
To
recall
the
most
recent
blood
pressure
measurement,
press
the
Print,
Mode,
Next
Patient/Clear/Cancel,
or
Blood
Pressure
Start/Stop
button.
Maximum
and
Minimum
Blood
Pressure
Ranges
The
maximum
and
minimum
blood
pressure
ranges
are
as
follows:
Measurement
Maximum
Minimum
Systolic
Pressure
250
mmHg
60
mmHg
Diastolic
Pressure
160
mmHg
30
mmHg
Mean
Arterial
Pressure
(MAP)
The
MAP
ranges
are
40
to
190
mmbg,
calculated
from
systolic
and
diastolic
data
(not
measured
directly).
Temperature
Thermometry
measurements
are
made
with
Welch
Allyn
SureTemp®
technology.
Oral
and
rectal
probes
utilize
single-use
disposable
probe
covers
that
limit
cross-contamination.
Oral,
axillary,
or
rec-
tal
temperatures
are
taken
using
Normal
or
Monitor
operating
modes.
Oral
and
axillary
temperatures
are
taken
using
the
blue
oral
probe.
Rectal
temperatures
are
taken
using
the
red
rectal
probe.
in
Normal
Mode,
the
thermometer's
microprocessor
predicts
body
temperature
in
approximately
4
seconds
for oral
temperatures,
10
seconds
for
axillary
temperatures,
and
15
seconds
for
rectal
temperatures.
When
using
Monitor
Mode,
allow
the
temperature
readout
to
stabilize
for
3
minutes
for oral
and
rectal
temperatures,
and
5
minutes
for
axillary
temperatures.
The
Monitor
Mode
continues
to
display
an
updated
temperature
as
long
as
the
probe
remains
in
place.
Settings
for
Fahrenheit
or
Celsius
scales
are
available
for
the
temperature
readings
display.
12
Welch
Allyn

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Welch Allyn Spot Vital Signs 420 Series and is the answer not in the manual?

Welch Allyn Spot Vital Signs 420 Series Specifications

General IconGeneral
BrandWelch Allyn
ModelSpot Vital Signs 420 Series
CategoryMedical Equipment
LanguageEnglish