Option 10 - System Protection
In some heating systems there may be a requirement
to protect the system by operating it once a day, for a
given period.
If system protection is selected the system will be
operated for a period as shown in system protection
time (mins).
System protection time is every day at 10.00am.
System protection default is OFF.
To enable the system protection mode enter the
Installer Options Menu (Refer to Installer Option 10).
Option 11 - System Protection time (mins).
System protection time can be set between 1 and 5
minutes (default 3 minutes).
To change this once a day on time enter the Installer
Options Menu (Refer to Installer Option 11).
How do I know when to change the batteries.
When the batteries start to run low a battery icon
will flash in the display, to indicate “low battery”
during this time the Digistat will function normally.
Replace with 2 x 1.5V (AA) Alkaline batteries.
When the battery icon alone is shown in the display,
the batteries are completely exhausted and the
Digistat will cease to function. Re-activate by
replacing the batteries. The RF link will automatically
be re-established.
How to replace the batteries
Remove the battery cover using a coin. Replace the
spent batteries with 2 x 1.5V (AA) Alkaline batteries
ensuring correct orientation. Replace the battery
cover pressing fully home.