03 04
•
Incendiary fires where the fire grows so rapidly that an occupant’s egress is blocked even with
properly located detectors.
When the Carbon Monoxide Alarm Sounds:
1. Operate the test/reset button.
2. Call your emergency services.
3. Immediately move to fresh air - outdoors or by an open door/window. Do a head count to check
that all persons are accounted for. Do not reenter the premises nor move away from the open door/
window until the emergency services responders have arrived, the premises has been aired out, and
your alarm remains in its normal condition.
4. After following steps 1-3, if your alarm reactivates within a 24-hour
period, repeat steps 1-3 and call a qualifi ed appliance technician
to investigate for sources of CO from fuel-burning equipment and
appliances, and inspect for proper operation of this equipment. If problems are identifi ed during
this inspection, have the equipment serviced immediately. Note any combustion equipment not
inspected by the technician and consult the manufacturer’s instructions, or contact the manufacturer
directly, for more information about CO safety and this equipment. Make sure that motor vehicles are
not, and have not been, operating in an attached garage or adjacent to the residence.
Package Contents
1 × Alarm Unit 1 × Mounting Bracket 3 × Screws
3 × Anchor Plugs 1 × User Manual 2 × Carbon Monoxide Safety Stickers
Actuation of your CO Alarm indicates the presence of Carbon Monoxide (CO)
which can kill you.
WARNING:
PHONE NUMBER
PHONE NUMBER
Technical Speci cations
Power supply 10-year sealed lithium battery
Sensor type Smoke: Photoelectric
CO: Electrochemical
Product life About 10 years
Safety standards UL 217 & UL 2034
Smoke sensitivity 0.97-1.79%/ft OBS
CO sensitivity 70 ppm: 60-240 minutes
150 ppm: 10-50 minutes
400 ppm: 4-15 minutes
Standby current < 8 μA (avg.)
Alarm current < 100 mA (avg.)
Best operating ambient temperature range 40-100 °F (4.4-37.8 °C)
Operating relative humi dity range 10%-85% (non-condensing)
Alarm loudness ≥ 85 dB at 9.84 ft (3 m) @ 3.2 ± 0.3 kHz pulsing alarm
Silence duration ≤ 9 minutes
Product Overview
CAUTION!
THIS SMOKE AND CO ALARM IS DESIGNED FOR INDOOR USE ONLY. DO NOT EXPOSE TO RAIN OR