13 14
Locations to Avoid
WARNING - This product is intended for use in ordinary indoor locations of family living units. It is
not designed to measure compliance with the occupational safety and health administration (OSHA)
commercial or industrial standards.
1. Do not install in garages, kitchens, furnace rooms or bathrooms! Do not install within 5 ft or 1.5 m of
cooking appliances.
2. Do not install within 3 ft (0.9 m) of the following: The door to a kitchen, or a bathroom that contains a
tub or shower, forced air supply ducts used for heating or cooling, ceiling or whole house ventilating
fans, or other high air flow areas. Avoid excessively dusty, dirty or greasy areas. Dust, grease or
household chemicals can contaminate the alarm’s sensors, causing the alarm to not operate properly.
3. Place the alarm where drapes or other objects will not block the sensors. Smoke and CO must be
able to reach the sensors to accurately detect these conditions. Do not install in peaks of vaulted
ceilings, “A” frame ceilings or gabled roofs. Keep out of damp and humid areas.
4. Install at least one (1) foot away from fluorescent lights, as electronic noise may cause nuisance
alarms. Do not place in direct sunlight and keep out of insect-infested areas. Extreme temperatures
will aff ect the sensitivity of the smoke/CO alarm. Do not install in areas where the temperature is
colder than 40 °F (4.4 °C) or hotter than 100 °F (37.8 °C), such as garages and unfi nished attics. Do not
install in areas where the relative humidity (RH) is above 85%. Place away from doors and windows
that open to the outside.
5. Smoke alarms are not to be used with detector guards unless the combination (alarm and guard)
has been evaluated and found suitable for that purpose.
Mounting Steps
1. Drill three Ø 6.0 mm holes in the wall or ceiling, then insert three plastic anchor plugs into the holes
with a hammer.
2. Attach the mounting bracket to the surface of the wall or ceiling with three screws and mount the
alarm into the bracket by pushing them together and twisting the unit clockwise.
3. Test the unit by using the Test/Silence button. Ensure the unit sounds in an alarm pattern.
Note
:
When attaching the alarm to the mounting bracket, twist the alarm clockwise fi rst, then fi rmly press
down on the alarm and rotate until it locks into place without any gaps. If not mounted properly, the
alarm will not turn on. If the alarm is not properly installed or the mounting bracket is removed, the
alarm will power off. When properly installed, there are no gaps between the bracket and alarm as
shown in the image below:
Note: This model is equipped with a feature that automatically activates the alarm when the
alarm is attached to the mounting bracket.
Weekly Test
WARNING!
1. NEVER USE AN OPEN FLAME OF ANY KIND TO TEST THIS UNIT. YOU MIGHT ACCIDENTALLY
DAMAGE OR SET FIRE TO THE UNIT OR TO YOUR HOME.
Gaps
No gaps
Improperly installed Properly installed