EasyManuals Logo
Home>Xinje>DC Drives>DP3F Series

Xinje DP3F Series User Manual

Xinje DP3F Series
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
20
6. Common troubleshooting
Fault
Reason
Solution
The power light doesn't
work
Power supply system error
Check the power supply
circuit
Low supply voltage
Increase the power supply
voltage
The motor doesn't work
The current setting is too small
Set suitable current
The subdivision is too large
Set suitable subdivision
Protection circuit action
Power on again
Release signal is low
Do not connect this signal
Not power on
Power on again
Motor wiring error
Check the wiring
No pulse signal input
Check the pulse cable and
signal voltage
Motor direction is error
Line failure
Check the circuit
Alarm light is on
Motor cable connection error
Wiring again
Voltage too high or too low
Adjust the power supply
voltage
Motor or driver damaged
Check the motor and driver
Motor torque is small
Acceleration is too fast
Decrease the acceleration
value
The model selection is not suitable
Select the model again