68
5-4.FX-XX auxiliary function
F0-XX
Back to out of factory settings
1. Clean the alarm
Set F0-00=1 to reset the alarm. When the alarm occurred, please find out the alarm reasons
then clean the alarm.
2. Back to out of factory settings
Please power off the servo drive before the operation.
Set F0-01=1, then press ENTER. No need to re-power the servo drive.
3. Clean the offset
Set F0-02=1 to clean the offset.
Jog (F1-00)
Make sure that the motor shaft is not connected to the machine before jogging!
When the servo is in jog run mode, gain and other parameters will join the process. Please
adjust the parameters according to the jog run status.