2
CD-C600
CD-C600
For U model
“CAUTION”
“F801: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 500mA,
250V FUSE.”
For C model
CAUTION
F801: REPLACE WITH SAME TYPE 500mA, 250V FUSE.
ATTENTION
F801: UTILISER UN FUSIBLE DE RECHANGE DE MÉME TYPE DE 500mA, 250V.
This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive
harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON
WHATSOEVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or
expose eyes to solder/flux vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.
1. Critical Components Information
Components having special characteristics are marked
and
must be replaced with parts having specifications equal to those
originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
Meter impedance should be equivalent to 1500 ohms shunted
by 0.15 μF.
All of the P.C.B.s installed in this unit and solder joints are soldered using the lead free solder.
Among some types of lead free solder currently available, it is recommended to use one of the following types for the
repair work.
Sn + Ag + Cu (tin + silver + copper)
Sn + Cu (tin + copper)
Sn + Zn + Bi (tin + zinc + bismuth)
Caution:
As the melting point temperature of the lead free solder is about 30°C to 40°C (50°F to 70°F) higher than that of the lead
solder, be sure to use a soldering iron suitable to each solder.
TO SERVICE PERSONNEL
Leakage current must not exceed 0.5mA.
Be sure to test for leakage with the AC plug in both polarities.
WALL
OUTLET
EQUIPMENT
UNDER TEST
AC LEAKAGE
TESTER OR
EQUIVALENT
INSULATING
TABLE
WARNING: CHEMICAL CONTENT NOTICE!
About lead free solder
WARNING: Laser Safety
This product contains a laser beam component. This component may emit invisible, as well as visible radiation,
which may cause eye damage. To protect your eyes and skin from laser radiation, the following precautions must
be used during servicing of the unit.
1) When testing and/or repairing any component within the product, keep your eyes and skin more than 30 cm/1 feet
away from the laser pick-up unit at all times. Do not stare at the laser beam at any time.
2) Do not attempt to readjust, disassemble or repair the laser pick-up, unless noted elsewhere in this manual.
3) CAUTION: Use of controls, adjustments or performance of procedures other than those specified herein may result in
hazardous radiation exposure.

Other manuals for Yamaha CD-C600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yamaha CD-C600 and is the answer not in the manual?

Yamaha CD-C600 Specifications

General IconGeneral
Frequency range10 - 20000 Hz
Signal-to-Noise Ratio (SNR)106 dB
Total Harmonic Distortion (THD)0.003 %
CD-RW playbackYes
File typeMP3, WMA
Device typeHiFi CD player
Product colorBlack
Dimensions (WxDxH)435 x 116 x 405 mm
Weight and Dimensions IconWeight and Dimensions
Weight6200 g