TABLE 7: BP036-072 HEATING CAPACITIES
Size
(Tons)
Air Over Evaporator
Coil
Capacity
1
& kW
Outdoor Temperature (°F @ 72% RH)
CFM DB (°F) -10 0 10 20 30 40 50 60
036
(3)
900
55
MBH 2.4 7.6 12.8 18.0 23.1 28.3 33.5 38.7
KW 1.6 1.8 1.9 2.1 2.2 2.4 2.5 2.7
70
MBH - 4.6 9.8 15.0 20.1 25.3 30.5 35.7
KW - 2.0 2.1 2.3 2.4 2.6 2.8 2.9
80
MBH - 2.8 8.0 13.1 18.3 23.5 28.7 33.8
KW - 2.1 2.3 2.5 2.6 2.8 2.9 3.1
1200
55
MBH 4.3 9.5 14.7 19.8 25.0 30.2 35.4 40.5
KW 1.5 1.7 1.8 2.0 2.1 2.3 2.4 2.6
70
MBH 1.3 6.5 11.7 16.8 22.0 27.2 32.4 37.5
KW 1.7 1.9 2.0 2.2 2.3 2.5 2.6 2.8
80
MBH - 4.6 9.8 15.0 20.2 25.3 30.5 35.7
KW - 2.0 2.2 2.3 2.5 2.6 2.8 2.9
1500
55
MBH 5.4 10.6 15.8 21.0 26.1 31.3 36.5 41.7
KW 1.4 1.6 1.7 1.9 2.0 2.2 2.4 2.5
70
MBH 2.4 7.6 12.8 18.0 23.1 28.3 33.5 38.7
KW 1.6 1.8 1.9 2.1 2.3 2.4 2.6 2.7
80
MBH 0.6 5.8 11.0 16.1 21.3 26.5 31.6 36.8
KW 1.8 2.0 2.1 2.3 2.4 2.6 2.7 2.9
048
(4)
1200
55
MBH 2.3 9.6 17.0 24.3 31.6 38.9 46.2 53.5
KW 2.0 2.2 2.4 2.6 2.7 2.9 3.1 3.3
70
MBH - 5.8 13.1 20.4 27.7 35.0 42.3 49.7
KW - 2.5 2.7 2.9 3.1 3.3 3.5 3.6
80
MBH - 3.1 10.4 17.7 25.0 32.4 39.7 47.0
KW - 2.6 2.8 3.0 3.2 3.4 3.6 3.8
1600
55
MBH 5.0 12.3 19.7 27.0 34.3 41.6 48.9 56.2
KW 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2
70
MBH 1.1 8.5 15.8 23.1 30.4 37.7 45.0 52.3
KW 2.2 2.4 2.5 2.7 2.9 3.1 3.3 3.5
80
MBH - 5.8 13.1 20.4 27.7 35.1 42.4 49.7
KW - 2.5 2.7 2.9 3.1 3.3 3.5 3.7
2000
55
MBH 6.4 13.7 21.0 28.3 35.6 43.0 50.3 57.6
KW 1.7 1.9 2.1 2.3 2.5 2.7 2.9 3.1
70
MBH 2.5 9.8 17.1 24.5 31.8 39.1 46.4 53.7
KW 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4
80
MBH - 7.2 14.5 21.8 29.1 36.4 43.7 51.1
KW - 2.4 2.6 2.7 2.9 3.1 3.3 3.5
060
(5)
1500
55
MBH 7.8 15.6 23.4 31.2 38.9 46.7 54.5 62.3
KW 2.9 3.0 3.2 3.3 3.4 3.6 3.7 3.9
70
MBH 6.2 14.0 21.8 29.6 37.3 45.1 52.9 60.7
KW 3.5 3.7 3.8 4.0 4.1 4.3 4.4 4.5
80
MBH 4.9 12.7 20.5 28.3 36.0 43.8 51.6 59.4
KW 4.0 4.2 4.3 4.5 4.6 4.8 4.9 5.0
2000
55
MBH 8.0 15.8 23.6 31.4 39.1 46.9 54.7 62.5
KW 2.5 2.7 2.8 2.9 3.1 3.2 3.4 3.5
70
MBH 6.5 14.2 22.0 29.8 37.6 45.4 53.1 60.9
KW 3.2 3.3 3.5 3.6 3.8 3.9 4.0 4.2
80
MBH 5.2 12.9 20.7 28.5 36.3 44.1 51.8 59.6
KW 3.7 3.8 4.0 4.1 4.3 4.4 4.5 4.7
2500
55
MBH 8.9 16.7 24.5 32.2 40.0 47.8 55.6 63.3
KW 2.3 2.5 2.6 2.7 2.9 3.0 3.2 3.3
70
MBH 7.3 15.1 22.9 30.6 38.4 46.2 54.0 61.8
KW 3.0 3.1 3.3 3.4 3.6 3.7 3.8 4.0
80
MBH 6.0 13.8 21.5 29.3 37.1 44.9 52.7 60.4
KW 3.5 3.6 3.8 3.9 4.1 4.2 4.3 4.5