EasyManuals Logo
Home>York>Chiller>R-407C Optimized

York R-407C Optimized User Manual

York R-407C Optimized
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
2
YORK INTERNATIONAL
3
YORK INTERNATIONAL
FORM 201.19-EG4
TABLE OF CONTENTS
Introduction........................................................................................................ 3
Specications .................................................................................................... 4
Accessories and Options................................................................................... 8
Temperatures and Flows .................................................................................. 11
Water Pressure Drop.........................................................................................12
Ratings ..............................................................................................................16
Physical Data.....................................................................................................34
Dimensions........................................................................................................38
Operating Weights (Aluminum Fin Coils) .......................................................... 82
Isolator Selection (Aluminum Fin Coils).............................................................83
Operating Weights ............................................................................................85
Isolator Selection ..............................................................................................86
Isolator Selection ..............................................................................................89
Isolator Details...................................................................................................92
Electrical Data ...................................................................................................94
Electrical Notes..................................................................................................105
Power Connection Options................................................................................106
Typical Control Wiring........................................................................................110
Application Data ................................................................................................112
Guide Specications..........................................................................................
...........................................................................................................................
Design Series
Type Start
Y = Star (WYE)-Delta
X = Across-the-Line
Voltage Code
17 = 200-3-60
28 = 230-3-60
40 = 380-3-60
46 = 460-3-60
58 = 575-3-60
Refrigerant
B = R-407C
YC A S 0208 E B 46 Y G
YORK Chiller
YC = YORK Chiller
Air-Cooled
Compressor Type
S = Screw
Nominal Capacity (tons)
Unit Designator
E = High Efciency
NOMENCLATURE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the York R-407C Optimized and is the answer not in the manual?

York R-407C Optimized Specifications

General IconGeneral
BrandYork
ModelR-407C Optimized
CategoryChiller
LanguageEnglish

Related product manuals